Version from 15.11.2005 (6.3.23.0)
- PAF: Data update from 27.10.2005 (UK only / Update 21.11.)
- Maintenance: Sometimes program crashed during version data creation,
if long file names w/o 8.3-alias were present. Error removed (V 6.4 only).
- Reorganisation: New planning areas: "Campaign-mark" and
"Discount-mark" (V 6.4 only).
- EyeExam/CL: R/L mark added for sketches and video-images (V 6.4 only)
- EyeExam: Software-interface to Keratron Scout available (V 6.4 only,
and only with advance version from Scout)
- EyeExam Instrument Interface: An additional interface
"File" has been integrated for the Topcon KR-7000P and 8100P.
- Rodenstock ImpressionIST-interface available (V 6.4 only)
Version from 21.09.2005 (6.3.22.0)
- CL: Old procedures have sometimes been incompletely displayed, error
removed (Update 07.10.)
- System: Sometimes an IPRO-program terminated after a
database-conflict message has been closed at another workstation. Error removed. (Update
07.10., V 6.4 only)
- System: Long waiting periods during "Compressing Eventlog"
in connection with workshop devices removed.
- Rodenstock ImpressionIST-interface available
- Appointment diary: Database-access conflict removed at CL -
Appointment Diary interface.
- Data backup: Detailed event protocol in separate file (V 6.4 only)
- Optovision WinOnline-interface available
- Patient: New print parameter /LASTPRDATE/ (Last procedure date) (V
6.4 only)
- Dispensing/CL: Accept examination data from last Glasses/CL: Option
added to copy Optom/Prescriber and prescription date as well. Option can be activated in
System-Preferences (V 6.4 only)
Version from 22.08.2005 (6.3.21.0)
- EyeExam Instruments Interface: Error during PD-transmission from
winIPRO to Visutron Plus removed.
- EyeExam: Interface to bonOptic EyeTop: Some data were missing for
spherical lenses. Error removed
- Manual: Is now called up locally instead through the network, after
problems arose caused by MS-Update (http://support.microsoft.com/kb/896054/)
- Reorganisation: During branches reorganisation, options for
Appointment diary reorganisation and EPoS bookings reorganisation have been added.
- Zeiss RVTerminal Interface: If the customer has the new RVTerminal or
an updated RVTerminal, the following data are now also included: CVD, CTR, form data as 36
point form
- winFit ordering system: CTR can now be included by winfit if
requested.
Version from 02.08.2005 (6.3.20.0)
- CL: Password query for "Change order" now handled as in
Dispensing.
Version from 14.07.2005 (6.3.19.0)
- Oculus-Interface Easygraph: Call-up error removed
- PAF: Data update from 22.06.2005 (UK only)
- EPoS Daily Settlement: Evaluation error patient frequency evaluation
acc. to entry date removed (patient frequency value was 0)
Version from 01.07.2005 (6.3.18.0/Update)
- Orders: New orders with prepayment have been set to "paid".
Error removed.
- Appointment Diary:
- Option "Check collisions" available: Check can be
deactivated for entering/editing new appointments.
- If more than one room is configured for an activity, then the room
will be preset which belongs to the current branch (only for branch networking).
- Patient Card File: Optional password for layout-changes (V 6.4 only)
- EPoS:
- When minimised: is now shown in task-bar instead desktop.
- Access to journal accelerated (V 6.4 only)
- Ordering system:
- to SA-Optic: Frame-finished orders now possible
- to Rupp+Hubrach: Ysis-lenses can be ordered (V 6.4 only)
- to Essilor: Ordering via XML-client DX3 possible
- Order status control: In the CL-order sums the CL-procedures were
sometimes missing, error removed
Version from 22.06.2005 (6.3.18.0)
- Main Menu: Button for EPoS added for EPoS workstations (V 6.4 only).
Open EPoS, re-start winIPRO if necessary
- EyeExam Instrument Interface: New driver for Nidek NT-2000 and
RKT-7700
- Reorganisation: Write errors are noted in Eventlog, wrong
error-messages during reorganisation of more than one areas with deletions removed.
- EPoS: Return can be locked by password (as void-password) (V 6.4
only)
- Third party program interface to Seiko Lens 3D available
- Third party program interface to Ecado: Various data exchange errors
removed
- Patient card file / Order survey: HA-orders and invoices integrated
(V 6.4 only).
Version from 06.06.2005 (6.3.17.0)
- EyeExam Instrument Interface: New driver for Topcon CV-2500
- Acoustic: International Version (V 6.4 only)
- Oculus-Interface: RAM-Drive D: is not used anymore.
- CL: Parameter for discounts: RDIS, RVAL-DIS, LDIS, LVAL-DIS,
PDIS-TOT, PVAL-DIS-TOT, PDIS, PVAL-DIS, DIS-TOT
- New: Optional Patient Language Mark (not for D)
Version from 10.05.2005 (6.3.16.0)
- Reorganisation: Performance improved
- Text modules with parameters /DATE/, /SYSDATE/, /TIMEOFDAY/
- Branch Networking:
- with Text Modules (together with rapid entry lists)
- if dial-up errors occur, the IPRO error window is not shown anymore,
but entry in branch error protocol
- Ordering System Hoyalog: Tracer driver is now re-started after
HoyaLog has been closed.
- Interface Zeiss RVTerminal: The PD measured is now accepted
- EPoS: Negative withdrawal amounts now possible
- System survey: Workstation number now shown in survey (except single
user)
- Patient Promotion: Error removed in Selection acc to action codes
- Eye Exam Module: Terminology changed: Anamnesis -> Case/Patient
history (UK only).
Version from 08.04.2005 (6.3.15.0)
- Campaign/Discount mark: Input without consideration of small/capital
letters.
- Patient Card File: Glasses ordering values now also shown if no
supplier selected.
- EPoS / Daily Balance:
- The accounting of NHS benefits can now be deactivated for the
"Claims NHS" account. Tick "inactive" for this account in the accounts
plan..
- Product number now also shown in the Void dialogue.
- Log-off of the newly logged-on user during closing of daily balance
is now automatically carried out.
Version from 30.03.2005 (6.3.14.0)
- Ordering system Rodenstock: Error messages during ordering lenses
with form removed.
- Diagnosis:
- Index creation accelerated.
- New: Temporary index repair. ATTENTION: Temporarily
repaired indexes have to be newly created later.
- New: Italian version.
Version from 17.03.2005 (6.3.13.0)
- Online Data Service: To access, customers need a valid maintenance
contract
- CL: With campaign-mark (V 6.4 only)
- Ordering system:
- Rodenstock: Program crashed - error removed
- Novacel and Essilor Edieyes: Coatings are now correctly transmitted
- EPoS / Daily balance: Export protocol can now be printed.
- Master Data - Branch: 2nd telephone number now available (V6.4 only)
- System Start: Delete Tmp*-directories
Version from 07.03.2005 (6.3.12.0)
- EyeExam: Measurement time/date can be edited
- Ordering system: Additional order data window: Other branch can be
set to receive delivery, all branches are shown.
- Reorganisation: Error in diary reorganisation removed.
- System: Date/Time-synchronisation between winIPRO-workstations within
a network (V 6.4 only)
- New: Text blocks for remark fields (V 6.4 only)
Version from 24.02.2005 (6.3.11.0)
- Patient Stoplight: Info-window with explanations by right mouse-click
- Patient Promotion: New column for CL-follow-up-time
- Order Status: Program speeded up
- EPoS/Daily Balance: Display error for alternative daily balance view
removed; Credit deposit now correctly shown.
- System-Preferences: VAT (V 6.4 only)
- CL / Reminder / Appointments: During loading of CL/Reminder a check
with appointments from the diary is carried out
- Country-legend expanded with flags and text
Version from 10.02.2005 (6.3.10.0)
- Dispensing / Frames: Inclination/Side angle can be entered in [mm] or
in [degrees] (V 6.4 only)
- Hoyalog ordering system: convFormat-error message removed
- New: Ipro-Vision (V 6.4 only)
- Statistics: Stock evaluation error for individual statistics removed
- Ordering system "Text file by email" available (V 6.4 only)
- Password system: New area "EPoS Export"
- Diagnosis: PRL.DAT removed (V 6.4)
- Patient card file: Preset current patient for patient search (V 6.4
only)
Version from 21.01.2005 (6.3.9.0)
- Online-Dataservice: Option to use other server for chains with own
dataservice-server.
- Oculus-Centerfield: Data have sometimes been damaged during storing -
error removed
- PAF: Data update from 25.11.2004 (GB only)
- New: Patient stoplight (V 6.4 only)
Version from 11.01.2005 (6.3.8.0)
- CL: LOT/Complementary refraction copying into dialogue corrected
- EyeExam Device Interface: new: Canon TX-F and Möller-Wedel AP-5000
Version from 17.12.2004 (6.3.7.0)
- Oculus-Interface: Image saving error from Keratometer/Easygraph
removed.
- Reorganisation:
- Plans an now be exorted. Import of plans included.
- New: Branches now possible. Limitatations: Only orders (EyeExam,
Glasses, CL, Reminder), no master data
- Errors during filing of changed orders are now documented in the
eventlog.
- EyeExam device interface:
- Nidek RT-1200: Sending of EyeExam to device must quicker.
- Error receiving EXT-data removed (Topcon KR-7000P)
Version from 16.11.2004 (6.3.6.0)
- Diagnosis: No local transfer/loading if different IPRO-installations
are present
- Maintenance: Internal copying after download now with detailed error
check and view.
- CL: For new entry by employee > 255 now correct transfer into job.
- PAF: Data update from 29.10.2004 (GB only)
- Reorganisation: Table creation speed increased; Error during
re-setting a large number of objects removed.
- EyeExam Device Interface:
- New driver for Tomey TL-2000 and TL-3000; also for Rodenstock
AL-4300, AL-4500 and AL-4600.
- Rodenstock CX-1000: Interim measurements are now being ignored.
- CVD is now only transmitted if refraction data are existing.
- Topcon KR-7000P: Time tolerance during receiving of EXT-data expanded
- Employee management: Working hours now recordable as preset for new
entries via context menu (Version 6.4 only)
- Patient card file / Acoustic: Crash because of invalid
supplier-entries. Problem removed.
- EPoS / Daily balance
- Patient frequency, cancellations etc are displayed in the daily
settlement again.
- Term change: Bookings without EPoS are now Bookings via payment
management.
- On the daily settlement, the Optom name can be printed instead of the
branch number.
- If the General account "Credit" is deleted, coupons and
deposits are still shown daily, but not automatically continued in the final booking.
Version from 19.10.2004 (6.3.5.0)
- Patient Card File: Dispensing: Columns for ordering values, eye
examination and prescription. CL: Columns for eye examination and prescription, according
to the tabs in the eye exam management.
- EPoS / Daily Balance:
- Check-digit for branch networing prepared.
- Program speed improved.
- In the title line of the daily balance it is now indicated, if
bookings w/o EPoS have been automatically completed.
- EyeExam/Device Interface: Nidek driver will wait longer for a
connection to the device. Extended protocol file added.
Version from 11.10.2004 (6.3.4.0)
- Date progression problem in Branch Networking solved.
- EyeExam Device Interface: new driver for Möller-Wedel VISUTRON 900.
- Reorganisation: Value range check for new entry: Export of all plans
with copy-button.
Version from 29.09.2004 (6.3.3.0)
- CL: Explicitly entered prices for individual lenses are now
preserved.
- Maintenance/Diagnosis: Automatic Stopp/New start off all drivers in
the network before/after maintenance and diagnosis (Version 6.4 only)
- Maintenance: Automatic Update of all active winIPRO installations in
the net after maintenance (Version 6.4 only)
- System start: New check for unequivocal workstation number
- New: Reorganisation of Insurance cos, clearing offices, Glasses for,
Indications and Care systems
- Dispensing/CL: Setting of "Picked up" and "Paid"
with active EPoS with the password "Clearing system". Deleting is only possible
with an existing password "Clearing system".
- Workplace management: 3-digit workplace number possible
Version from 13.09.2004 (6.3.2.0)
- EPoS:
- A Deposit / Withdrawals survey can be produced, select
"Extras" from the menu.
- Generalisation of the statistics accounts in the standard view to
assets possible (in daily settlement).
- The branch designation is now shown in the daily settlement printout
(Journal,...)
- Standard account plan extended by a difference account fot hidden
proving cash.
- A password can be activated for the modes of payment preferences.
- Statistics: Sales campaign and Discount marks are now supported.
- New: Reorganisation Patient characteristics
- Patient card file: Empty field in DOB of insured now possible
- Octopus PeriTrend-Interface: Problem with new entries removed.
- PAF: Data update from 26.08.2004 (GB only)
- Oculus-Interface: Import from A: in spite of other selection - error
removed
- EyeExam: Employees > 256 were not correctly saved in the basic
data. Error removed.
- EyeExam Device Interface: Error correction in driver for Nidek
RT-1200 added.
- Diagnosis: Phantom error at "Error GlobIDs" removed.
Version from 26.08.2004 (6.3.1.0)
- Oculus-Interface: Export/Import-folder freely selectable, Export data
sending by email.
- New: Prescriber reorganisation
- New: Reorganisation of suppliers for Lenses, Frames, CL, Merchandise,
Hearing Aids (Version 6.4 only)
- EPoS:
- Automatic closing for bookings without EPoS can now be configured.
- Deficiencies are now marked red in proving cash
- Zero bookings and patient names can be suppressed in the journal
- New password for EPoS preferences, at the moment valid for zero
bookings and modes of payments.
- Line feed error during accounts plan printing removed.
- In the standard accounts plan, an account for money transfer (1360)
has been added.
- Program error on automatic withdrawal during proving cash removed (In
special cases no booking took place).
- Password system: New area "EPoS" for preferences (s.a.)
Version from 29.07.2004 (6.3.0.0)
- New: Employees Reorganisation (Update 03.08.)
- EyeExam bonOptic EyeTop: Problem with wrong decimal place in transfer
data removed (Update 03.08.)
- Diagnosis: new: Repair Database, Com.Dat. ATTENTION: Do not use
without request from the IPRO-Hotline!
- Appointment diary: Priority message removed when new entry from CL.
- EPoS: Patient name in journal can be hidden.
- CL:
- Trial lens can be shown in invoice window.
- New tab-column "Addition/Height"
Version from 13.07.2004 (6.2.15.0)
- EPoS
- Warning if system date and IPro-date are different.
- Booking date now shown on closing.
- If drawer is opened by pressing the drawer button, a zero-booking is
carried out.
- Branch is shown on the daily settlement printout
- Password allowed for evaluations
- Statistics accounts can be defined
- Automatic withdrawal bookings via target accounts possible.
- Alternative representation of daily settlement can be selected.
- Updating of credit sales / pre-payments possible
- Conversion to 6-digit accounts possible.
- SuperUser-Password does not have priviliged access to password system
management anymore.
Version from 24.06.2004 (6.2.14.0)
- CL/Form printing: Parameters for the last 20 procedures (was: 10)
- Consecutive bill numbers (Version 6.3 only)
- Windows-colour scheme now used everywhere (Version 6.3 only)
- EPoS
- Password for daily turnover prepared
- Group assignement for merchandise now more flexible
Version from 01.06.2004 (6.2.13.0)
- CL: Merchandise with trial lenses was not shown in settlement window,
error removed.
- Reminder: Window for sending of export files improved.
- Appointment Book: Occasional crashes during appointment editing
removed.
Version from 11.05.2004 (6.2.12.0)
- EyeExam:
- new category: Tonometer (Version 6.3 only)
- error in measurement view (CL-complementory) removed.
- EyeExam Device Interface: new drivers for Canon RL-10, Rodenstock
RX-900, Rodenstock CX-1000
- Opsys Interface: Branch specific patient numbers are now transmitted
to Opsys (Version 6.3 only)
- EPoS:
- Password setup for daily closing now possible
- Problems with receipt-form assignment in branch networks removed
- EPoS functions accelerated
- System start: Current workstation configuration copied to server
during each start-up.
- Oculus-Interface: Centerfield: IPro-error message with data from new
Centerfield-software-version removed.
- Reminder:
- New selection criteria: All/Only own branches
- Set/Delete branch during setting/deleting reminders.
- Glasses/CL: Acuity fields larger (for GB)
- Password system: Areas renamed:
- Area 16 "EPoS Cashbook + Parameter" -> "EPoS daily
balance"
- Area 20 "EPoS long term statistics" -> "EPoS daily
turnover"
Version from 22.04.2004 (6.3.11.1)
- EPoS:
- Sporadic empty bookings during cashing repaired.
- The consecutive cashbook-number is now printed on the daily
settlement and turnover.
- Reminder: Branch added
Version from 06.04.2004 (6.2.10.0)
- Glasses: Re-setting of "Settled" and re-entering into the
Insurance co. settlement was sometimes not stored. Error removed.
- Branch Networking: Extended status diagram view can now be configured
in "Extras-Options"
- EPoS:
- Error during start-up in branches removed.
- Additional information in daily settlement.
- Coupon account is now continued.
- Date now shown in header on printout.
- Various improvements for creating accounts.
- HP-Laserjet printing problems removed.
- Multiple creation of the same account now impossible.
- Bookings without EPoS can now be hidden.
- Branch number display error in the journal removed.
- EyeExam device interface: New driver for Rodenstock CX-200
Version from 17.03.2004 (6.2.9.0)
- Branch Networking: Various optimisations plus extended error handling
during processing of other branches data.
- EPoS:
- Customer-display scheme available through online dataservice.
- Password query during void.
- Change is being removed from daily settlement calculation.
- A separate overdue fines account can now be set up.
- Print margins optimised for journal printing.
- Error in EPoS opening balance via time selection removed.
- EyeExam: Prism-Base is now mirrored during refraction data copying R
<-> L
- EyeExam Devices Interface:
- Error during opening a COM-port with 1 stopbit removed.
- Error scanning RX-202 data removed.
- Handshake for ACUITAS-driver changed.
- New drivers for Topcon CV-2000 and Nidek RT-2100
- Patient Card File: Program sometimes crashed if several CL-orders
with several procedures from the same order date were present. Error removed.
- Patient Card File (UK-only): Automatic initials for new entries
repaired.
- New CL-Text Parameters: /CLFOLDATETIME/, /CLPEMP/, /PEMP-x/ S
Version from 01.03.2004 (6.2.8.0)
- EPoS:
- Minor changes regarding the customer display control and the daily
balance.
- Bank accounts and expenditure accounts extended to a max. of 99
accounts.
- Mailshop-ordering control now also available for version 6.2
- Glasses: During exiting a glasses order, the program sometimes
crashed if a facette window was open before, error removed.
- Appointment diary: Workplace-specific option "Use current user
for new appointment entry" now available.
Version from 20.02.2004 (6.2.7.0)
- EPoS (Version 6.3 only):
- Daily balance: New tab "Daily settlement" added for the
totals of the daily receipts, expenditures and claims.
- Button overlapping in the journal removed (void-dialogue).
- Representation error during balance editing removed (proving cash).
- Proceeds accounts are now sorted by account number (daily turnover).
- 10.000 Euro/£ booking limit removed.
- If the nominal balance value for a mode of payment is set to -1 (EPoS
Preferences), all book values will be automatically continued during the daily balance.
- In the journal, the balance is shown for every order.
- For the daily settlement, three additional general accounts are
required: EPoS, Bank and Expenditures
- "Drawer via printer driver" option available in
preferences.
- Order refund via EPoS available
- EyeExam: Software-interface to Octopus PeriTrend added (Version 6.3)
- EyeExam device interface: New drivers for Nikon REMOTE VISION and
Rodenstock CX-500
Version from 03.02.2004 (6.2.6.0)
- EyeExam: Problem during saving of long text in the remark field
removed (Update 09.02.)
- Oculus-Interface: Sagitta radii assignement temp.-nas. corrected
(Update 06.02.)
- EyeExam Device Interface: New driver for Canon R-10 (6.3) (Update
06.02.)
- EPoS:
- Error during "Void" removed.
- Password query for daily turnover is now supported.
- Private account is now correctly displayed in the journal.
- EyeExam: Drag & Drop of anamneses, anamneses sheets with return
values (refraction) now possible.
- Video:
- Problem with image size for Flashbus-video cards in 800x600 removed.
- Improved memory management for video-clip management (recording).
- Reminder: Data export for mail-merge letters, export/sending by email
Version from 22.01.2004 (6.2.5.0)
- Branch Networking: Initial status of a system is now highlighted with
colours in the status diagram
- EyeExam Device Interface: New drivers for Topcon RM-A3000 and
Rodenstock RX-520 l
- Reminder: Reminder selection sometimes crashed if periods were not
filled correctly in the setup. Error removed.
- EPoS: Various improvements (Version 6.3 only)
- Branch Networking: Branch logo bitmap can be assigned to a branch
(Version 6.3 only)
- Workstation management: Option "Workplace protected"
available (Version 6.3 only)
- Glasses/CL: Anamnesis now possible directly from order (w/o EyeExam)
(Version 6.3 only)
- CL: Sketch and Slitlamp are now order-related instead of
procedure-related. Unnecessary buttons removed from CL-procedure screen. Procedure-survey
now larger. Drag & Drop of Contact Lens data from EyeExam now possible (Oculus, Bon)
(Version 6.3 only)
Version from 14.01.2004 (6.2.4.0)
- EyeExam Device Interface:
- Tomey RT-6000: Assignment of horizontal and vertical cornea radii
corrected.
- New driver for Zeiss Humphrey ACUITAS
- EyeExam: Crash on opening old measurements removed
- Video: Remark about not-installed Video-card now in window header
instead of own window.
- Barcode: IT 3800 via USB is now supported.
- Patient Screen/EyeExam: Colours changed in tree view for clearer
representation: Right side=Red, Left side=Blue
Version from 07.01.2004 (6.2.3.0)
- EPoS: Daily balance revised.
- Video: Flushbus video card improved.
- Statistics: Direct cash sales at EPoS are now supported.
- Patient screen:
- Tab-view accelarated.
- New column "Next delivery" for CL-tab
- EyeExam device interface: New drivers for Rodenstock PHOROMAT 200/500
and Nidek RT-1200
Version from 16.12.2003 (6.2.2.0)
- Barcode: CPT-711: Conflict at serial interface removed.
- Patient Card File/Tree view: Error in EyeExam No. representation
removed
- EyeExam Report:
- Error during saving of measurement type "Anterior Eye
Segment" removed.
- Error during saving of Exam sheets with Remarks texts > 295
characters removed.
- IPROdos: Patients can only be deleted in winIPRO from now on
- EyeExam Device Interface: Error in driver for Tomey RT-6000 removed
Version from 05.12.2003 (6.2.1.0)
- PAF: Data update 11/03 (UK only)
- Barcode: Barcode with DOS-compatible Job-number can now be processed.
- EyeExam: Data copying Glasses/CL: Minus cylinder conversion
- Patient card file: Glasses/CL can be sorted acc. to order date
- Maintenance and data service changed to new URLs on Port 80, to avoid
problems with various firewalls
Version from 20.11.2003 (6.2.0.0)
- EyeExamManagement Glasses/CL: In the exam tabs it is now shown if
values are exisitng (*)
- CL: Text parameters for the last procedure of an interim account now
refer to the last procedure of the interim account.
- EyeExam: Data saving corrected for the last edited measurement.
- Diagnosis: Create/Reconstruct Index accelerated.
- Appointment diary: Employee locks were not shown if an employee
filter was active and the employee part of that group. Effect removed.
- EyeExam device interface:
- New drivers for Tomey RT-6000, Canon RK-5, Nidek ARK-700.
- Error during window minimising removed.
- Barcode: Problem during reading out of the Barcodes removed. This
error only happened with memory scanners.
- Statistics: Error in weekly evaluation removed.
Version from 24.09.2003 (6.1.14.0)
- EyeExam:
- Safety query if cancel is selected.
- OK/Cancel/Print buttons added to anamnesis sheets.
- Anamnesis sheets available in Online-Data service.
- EyeExam Device Interface:
- New driver for Canon RK-3.
- Addition transfer corrected for Visutron Plus.
- onnected device detection error removed.
- EyeExam/CL: Radii transfer added to Oculus EasyGraph interface.
- Patient card file: Postcode-lookup integration added (PAF)
Version from 16.09.2003 (6.1.13.0)
- Branch Networking: Error intercepted if new branch entry is faulty
- EyeExam Device Interface: New: Canon R-50
- Eye Exam bonOptic EyeTop: Patient name transfer corrected
Version from 29.08.2003 (6.1.12.0)
- EyeExam Instruments Interface: New: Topcon KR-7000P and KR-8100P, and
Canon R-30
- EyeExam Report:
- Form printing with sub-forms.
- Devices-Measurement Type-Assignment / Output to IPRO: Keratometer:
Refraction data can now also be received.
- Diagnosis: "Programs to Server" can now also copy
VBX-files.
- Barcode:
- Serial scanners (CPT-711) adapted to a lower Baud rate.
- The most recent order will be selected if an order number appears
several times.
- EAN 8 is scanned as EAN 13.(CipherLab CPT-711); Baud rate set to
38400.
- System parameter "Glasses security" now with password
protection.
Version from 31.07.2003 (6.1.11.0)
- Diagnosis: Extended index test error detection improved.
- EyeExam Device Interface: New: Canon R-20/22 and RK-1; and Rodenstock
CX-520 and RX-202
- EyeExam: New: Software-interface for bonOptic EyeTop
- EyeExam: New category: Visus (espescially for UK)
Version from 24.07.2003 (6.1.10.0)
- EyeExam Device Interface: New: Canon RK-F1 and R-F10
- Video: Microsoft WDM Image Capture (Win32) driver is now supported
for XP.
- Statistics: New Patients evaluation is now available as a standard
statistics.
Version from 17.07.2003 (6.1.9.0)
- Barcode: EAN13 code-errors removed in stock control.
- EyeExam: Error handling during new entries corrected (invalid
measurement types led to invalid data)
- EyeExam Device Interface: New: Möller-Wedel VISUTRON PLUS
Version from 10.07.2003 (6.2.8.1)
- Dispensing: Currency fields were justified left
- Oculus Interface: Process-control optimised
- EyeExam-device interface: Problem with double data records removed.
Database crash problem during data receiving removed.
- Optom Master Data: Special characters are now currectly displayed.
- Statistics: Title and first name of employee are now also included
into evaluations.
Version from 01.07.2003 (6.1.7.0)
- Master data - Systems: Now also available for users without branch
networking.
- Master data - Optoms: Last name field extended to 25 chars, List view
adapted (V6.2 only)
- Oculus-Interface: EasyGraph added (V6.2 only)
- Statistics: Standard statistics can now be opened without
write-protection
Version from 20.06.2003 (6.1.6.0)
- CL:
- Automatic exam data transfer corrected (was left = right)
- CL-orders with exam data could not be deleted
- Patient Card File: Problem with "empty tabs" after order
deleting corrected.
- My dr.ipro: Access problems corrected for access data with '/'
- Exam Report/Device Interface: "Send"-button after pressing
now deactivated as long as communication with device runs.
- Emil: Optimised (Branch networking, Order control, etc)
Version from 04.06.2003 (6.1.5.0)
- Master data - Optom: Address particulars extended (V6.2 only)
- Patient screen: CL-order status for new entries is now set to
"Ready, but not yet picked up" (green point). The "Ready" status
doesn't exist for CL-orders, therefore the "not ready" status was never shown.
- Eye Exam Report (V6.2 only):
- Device communication / Compatibility interface for instruments which
were connected to the DOS-Eye Exam Report.
- Anterior Eye Segment: Window contents got lost during drag and drop,
repaired. Sorting order in card-file tab corrected. Automatic acceptance of last
- EyeExam corrected.
- Wheel-mouse now supported.
Version from 20.05.2003 (6.1.4.0)
- Email-receiving error removed (branch networking, ordering by email):
Version from 14.05.2003 (6.1.3.0)
- Eye Examination Report (V6.2 only):
- XML4-registration now locally per workstation
- PD preset from patient master data (for new manual entry
PD-measurement)
- Tree view: Addition and Prism are now shown, if available
- Program crash removed (Exam report crashed during closing if
XML-sheet wasn't closed properly)
- Problems in multi-currency mode removed
- Branch networking: Email-receiving optimised, emails are now picked
up much faster.
Version from 28.04.2003 (6.1.2.0)
- System start: Check for valid system date added
- New: Multiple currencies capability: Exchange rate input in winIPRO
system preferences. Euro/£ popup extended to foreign currency popup window (V6.2 only)
- CL-follow-up: Appointment diary button removed if diary not installed
- Eye Examination: Import from Dos Examination corrected: History and
Symptoms, anterior eye segment (V6.2 only)
Version from 16.04.2003 (6.1.1.0)
- Maintenance: Network database check optimised
- Dispensing / Lens entry: Corrected "Enable / Disable"
function of the "Additional supplier order data" button. It now works correctly
for orders with only one lens.
Version from 28.03.2003 (6.1.0.0)
- New: Eye Examination Report and Management, Barcode (V6.2 only)
- CL: New text parameters RSUP-CUNO, LSUP-CUNO (right and left lens
supplier customer numbers)
- Video: Footswitch now supported. By pressing Enter, a photo will be
automatically created.
- Statistics: Statistics can now be deleted without activated editor.
- Statistics can now be manually updated by pressing the right mouse
key in the staistics directory.
- IPROdos EPoS: winIPRO stock numbers are now
displayed again on receipt printouts
Version from 19.03.2003 (6.1.22.1)
- Data Service: Dialogue improved
- Appointment Manager: Time settings for employee-locks with a time
series are now generated correctly.
- Video: Error on image loading within a network removed corrected
Version from 11.03.2003 (6.0.21.0)
- CL: Interim bill function corrected
- Patient Card File: Card reader button deactivated if no card reader
module present.
- Appointment Manager: Remarks in Day View can now be switched on/off
per workstation.
- Opsys interface: PD-transmission error corrected
- Price lists: Texts for prism and cylinder surcharges now in correct
font
Version from 13.02.2003 (6.0.20.0)
- Branch Networking: Several improvements (update for branch networking
systems recommended) (V6.1 only)
- Voucher codes: Import of voucher codes directly from CD now possible
- Opsys interface: Form is now transferred from Opsys to IPro with 36
points
- IPROdos EpoS: Accounting of sunglasses and not order related frames
corrected
Version from 15.01.2003 (6.0.19.0)
- Data Backup: Error removed for file names > 100 characters
- Video: Error during picture loading removed
Version from 17.12.2002 (6.0.18.0)
Version from 10.12.2002 (6.0.17.0)
- Branch Networking (V6.1 only): Mail send function with automatic
timer control optimised.
- Video: Printer selection added (V6.1 only)
- Patient Card File: Country selection switches Postcode legend
Version from 13.11.2002 (6.0.16.0)
- Diagnosis: Database priority after loading older local data removed.
- Diagnosis: Local transfer corrected in branch networking environment
(V6.1 only)
- Data backup: Extra backup set for computer replacement (V6.1 only)
- Video: Image saving problem resolved.
- New: EyeLink / EyeCap-Interface
- Branch Networking: Automatic hotline notification implemented for
various branch networking problems (V6.1 only)
- Lens consultation: Calling up of Essilor-Opsys-Software (16-Bit) from
winIPRO adapted.
- Ordering: Calling up of Essilor-Edieyes-Software (16-Bit) from winIPRO
adapted
Version from 02.10.2002 (6.0.12.0)
- Diagnosis: Database priority after loading older local data removed.
- Video: Flashpoint 3Dx now supported under Win2k.
- Data backup: Various protocol files added for backup via Network.
Version from 25.09.2002 (6.1.11.1)
- Branch networking (V6.1 only):
- Multiple instances are now handled automatically ("winet already
running" note is not displayed anymore)
- automatic priority for branch networking w/o email-synchronisation is
now taken from system management
- various special errors during Internet-communication are now
automatically recognised, handled and recorded.
- winIPRO: Cylinder entry field now allows
two digits. Attention: For cylinder >= 10 the first digit will not be
displayed in IPROdos (V6.1 only)
- Dispensing: Wrong Visus-acceptance from "preset from old
sale" corrected
- Email: Timeout problems during receiving of several mails removed.
Version from 12.09.2002 (6.0.10.0)
- For local transfer data the maintenance workstation is always set to
1.
- Connecting to dial-up network: Error message removed in the automatic
mode if "Internal Account" (esp. branch networking) has been set; now only EvLog
entry.
Version from 04.09.2002 (6.0.9.0)
- Branch networking (V6.1 only): Status diagram representation adapted.
- Form printing prism: Cumulative rounding errors during repeated
cart-pol conversions corrected.
Version from 21.08.2002 (6.0.8.0)
- New: winIPRO Password-system (V6.1 only)
- Ordering system: Input options in the facette-position window are now
adapted to the ordering system selected, if frame-finished has been selected.
- CL:
- For "New entry with this preset" ordering data are no
longer copied over.
- Fitter pre-set with logged-on user.
- New procedure now includes follow-up date of the last procedure, if
not already in the past.
- Reminder:
- Progress bar during selection.
- New parameters /RMSELECDATE/, /RMEFFDATE/
- List printout.
- Card file order survey: Prescriber with prescription date, if
external prescription
- Live date-resetting on date change (winIPRO running)
- Euro available for CH and UK
- Branch networking (V6.1 only): Branch networking protocol is archived
- Email: Email provider with SMTP-authentification are now supported
(not Compuserve!)
- Dispensing: Plausibility check extended for frame-finished w/o traced
form.
- New: winIPRO Video (V6.1 only)
- Main menu: Optional parameter -C for additional text in header
- Statistics: CL-orders evaluation corrected.
- CL: Negative eccentricity now possible.
- Diagnosis: SystemInfo in event protocol
Version from 11.07.2002 (6.0.5.0)
- winIPRO: Now checks the correct readability of IPROWING.INI during
startup. If an error is found (caused by Win95/98 network access errors) startup is
instantly aborted without initialising the supposed new indexes.
- Patient Promotion: Error corrected: Incomplete selection acc. to
frames supplier, if the order has been recorded with winIPRO stock control.
Version from 24.06.2002 (6.0.4.0)
- Win Stock Control:
- Data check/repair (Preferences - Data check)
- New evaluation type: Stock movement lists
- Short Info: Re-print labels, enter required qty.
- Stock / Acoustic / Online Data service: Online-loading of service
catalogues possible
- Diagnosis: new: Manual / Automatic local transfer
- Patient promotion: Old: During a CL-selection acc. to billing date
orders w/o billing date were not selected. New: If no billing date exists, order date is
used, if no order date
exists, prescription date is used.
Version from 27.05.2002 (6.0.3.0)
- Upgrade IPROdos -> winIPRO: Delete file version entry in
IPROWING.INI if DOS database is detected.
- Maximum number of local branches raised to 10
- Appointment diary: Clashes check refined during appointment entry
(Clash cause is shown in detail)
- CL/Keratograph:
- Workaround for MS-problems with Win2k workstations at Win2k-server.
- Problems with importing from diskette under Win98 solved.
- Dispensing: Additional order data: Problems with storing of insurance
preset (with right-mouse click) solved.
- Data backup:
- Extended file selection dialogue for single file restore (right
mouse-click for search window).
- Option to backup Ipro-data without programs and blobs added
(ATTENTION: not recommended, as database is not completely saved).
- Dispensing: Error message "invalid front curvature" removed
for newly entered orders.
- Event-protocol viewer: Search-dialogue added. File selection added to
"send email" dialogue.
- New patient text parameter /SEX/
- Employee-log-on added to V 6.1 (Branch networking version)
Version from 24.04.2002 (6.0.2.0)
- Spectacles: Frontal Bow can now be entered with sign and decimal
place.
- winIPRO programs in Windows Task Bar
- CL: Changes of order date now as in Spectacles
- Data backup: Problems backing up from Network-directories removed.
Version from 03.04.2002 (6.0.1.0)
Version from 22.03.2002 (6.0.0.0)
- CL: Remark fields can now all be directly edited; increased
readability.
- Statistics: Error in frame material classification removed
(plastic/metal).
Version from 22.02.2002 (5.5.26.0)
- CL: Crash on opening settlements with interim accounts repaired
- Password query repaired
Version from 06.02.2002 (5.5.25.0)
- winIPRO-IPROdos: Extended character set compatibility
- New: winIPRO workstation management (V 6.0 only)
- Appointment manager: Alarm pre-warn time now with 4-digit field
- Data backup/Restore: "Please insert data medium 2" error
removed if restoring from only one medium
- Diagnosis: Extended access tests prior to every data
loading/transfer. New "Abort-Retry-Ignore" dialogue if errors occur.
- Maintenance: Prot with IPRO-directories only now possible
Version from 17.01.2002 (5.5.24.0)
- Diagnosis: Adapted to Appointment Manager extensions
- CL: Shows "lost" merchandise again (e.g. if last procedure
date has been changed)
- CL: Terms/Form parameters changed in Fitting window:
- Divid -> Ht (Height), /RCDIVID/ -> /RCHEIGHT/
- Stab -> Rotn (Rotation), /RCSTAB/ -> /RCROTN/
- Vsc -> Vis, /RCCVSC/ -> /RCCVIS/
- Vcc -> VA, /RCCVCC/ -> /RCCVA/
Version from 07.01.2002 (5.5.23.0)
- Diagnosis: New functions added.
- CL: Division of CL-prices in L/R only if total price is changed
Version from 30.12.2001 (5.5.22.0)
- CL Oculus Interface extended: Easyfield
Version from 20.12.2001 (6.0.21.1)
- Order Status Control: Program does not cancel anymore if a locked
order is being edited. Now a query appears: Do you wish to continue nevertheless?
- Voucher codes now with description fields.
Version from 05.12.2001 (5.5.20.0)
- CL Oculus Interface extended: ImageCam, Centerfield and Twinfield are
now supported
Version from 22.11.2001 (5.5.19.0)
- Conversion from IPROdos to winIPRO after maintenance
(Wartg32). Request to restart server database in winIPRO (all versions).
- Maintenance CD/Online: Read only attributes are now deleted
during copying.
Version from 14.11.2001 (6.0.18.1)
- CL: Keratometer data export now also possible to path (if set in the
system parameters)
- Version 6.0 only: System will demand re-start of database after
maintenance.
- Version 6.0 only: Problem in DOS merchandise stock resolved.
- Diagnosis: Index rebuild-mechanism extended.
- Appointment Manager: Alarm function repaired. To activate previously
entered appointments: Diagnosis - Reorganisation - Reconstruct Index - TKWRNIDX.DAT
Version from 07.11.2001 (5.5.17.0)
- EPoS: EC-cash payments in EURO inplemented.
- IPROdos: Employee management adapted to winIPRO
- Dispensing: If old sale is used as preset, the block mode
(active/passive) is no longer adopted.
- Data backup: Backup/Restore on tape drives deactivated. Can be
reactivated after hardware compatibility check.
Version from 12.10.2001 (5.5.15.0)
Version from 04.10.2001 (5.5.14.0)
Version from 25.09.2001 (5.5.13.0)
Version from 17.09.2001 (5.5.12.0)
- Statistics:
- Time profile is now automatically adapted to the current date during
evaluation.
- To change the time profile, a monthly survey can be called up with a
right mouse-click.
- Glasses/CL: For 'picked up' and no NHS-vouchers, 'Prescription on
hand' will be set to 'yes' to remove order from the order status control.
- Patient promotion: Lens criteria: No switching to 'Finish' anymore if
winIPRO has been installed.
- CL: Item data consistent IPROdos <-> winIPRO
Version from 06.09.2001 (5.5.11.0)
- new winIPRO version code.
Version from 04.09.2001 (5.5.10.0)
- Patient card file: Patient merging repaired.
- Diagnosis: New: Network-Performance-Test.
- Statistics: Form printing optimised and extended.
- Contact lenses: new form printing parameter /RVD/ : Vertex Distance
from refraction.
Version from 13.08.2001 (5.59)
- Statistics: EpoS evaluation improved.
- Form printing: Prisma X/Y now empty if prism is missing, not
"0.00".
Version from 06.08.2001 (5.58)
Version from 30.07.2001 (5.57)
- CL-card file: For converted orders, the order number which was
generated during conversion is now used.
- Contact lenses: For a "New procedure" the care system is
now copied over from the last procedure; the complementary refraction is not copied over
anymore.
- Branch networking: Changes made for insurance cos. and prescribers
are now also recorded from winIPRO.
- Order status control: The selection window for workshop employees has
been extended to 255 possible entries.
Version from 17.07.2001 (5.56)
- Statistics: "Explorer" renamed to "Directory"
Version from 06.07.2001 (5.55)
- System check: Wrong error messages regarding hard disk space removed
- Data backup: Error during start removed
- Online/CD Maintenance: Function "Continue aborted
maintenance" optimised
Version from 28.06.2001 (5.54)
Version from 21.06.2001 (5.53)
- Diagnosis: Minor improvements
Version from 20.06.2001 (5.52)
- Online Maintenance: Confirmation now not before transmission is
complete
- winIPRO: System checks are now carried out during program start.
- Patients from conversions can now also be joined together.
Version from 07.06.2001 (5.51)
- Data backup to tape streamers: Various hardware adaptations, verify
included in backup.
- winIPRO Statistics: Update of standard statistics
- IPROdos-EpoS:
- Orders that are paid in Euro and where a currency difference >
0.01 arises, are set to fully paid.
- VAT rate determination for merchandise corrected.
- The amounts on the receipt output for automatic withdrawals are now
shown in long format.
- winIPRO Diagnosis: Now with database test. Index tests are grouped
according to database files. Protocol printing. Batch mode.
- Lens input: Filter ARs are now included in the AR line instead of the
tint line.
- Opsys: Lens copying from Opsys to Ipro improved
Version from 22.05.2001 (5.50)
- eMail: Takes the preferences from the winIPRO-Internet-parameter.
- Glasses: Frames representation of traced frames shows logo of tracer
manufacturer
- Glasses: Graphical lens representation: Thickness calculation
revised.
- Glasses: New interface to video centration program Visupoint/visuReal
- Master data/Order status control: Word processor can now be directly
called up with the selected form from the printing dialogue.
- Zeiss Winfral Interface: Problems with brown glass lenses solved.
- winIPRO/IPROdos calculator management rounding factors: Rounding can
now be set to Euro (Cts)
- Diagnosis: Database reorganisation now under winIPRO.
- Patient card file: During patient deletion their orders can be
assigned to another patient.
Version from 07.05.2001 (15.52)
- Voucher codes: Saving of first entry corrected.
- Video consultation: An archive reorganisation is now carried out
during program termination to reduce the hard disk space needed for the archive.
- CL-module: Stabilisation axis value range extended to 0-360°.
- EPoS: Screen output corrected if reduced VAT has more than 4 digits.
The pause text on the customer display is now displayed after closing the till.
Version from 25.04.2001 (15.51)
- Maintenance: Running IPROdos is now detected and must be closed
before maintenance will continue.
- EPoS: Corrections for customer display under Win98 and Win2000
Version from 11.04.2001 (15.50)
- Patient titles as text field with drop-down list
- Statistics: The mark 'Patient since' is now supported
Version from 30.03.2001 (15.59)
- Visus entry in x/xx format (GB)
- Lens input: The availability of a lens is now correctly determined in
cases where the availability differs for different sphere values / powers combinations
within the same diameter
Version from 26.03.2001 (15.58)
- Glasses: Orders with Old Card File or Quotation status can now be
excluded from the Ophthalmic Certificate List.
- Lens input: An error message is now displayed, if a surcharge for a
cylinder value has to be determined which is outside of the cylinder range of the basic
lens.
- Voucher codes/values: Problems with Index MISPOSBZ removed.
- IPROdos EPoS:
- Different VAT rates are now processed for Hearing Aid orders (only
with installed Hearing Aids module); new proceeds accounts added; VAT is shown in the
cashbook and receipt
- Creation and email transfer of extended cashbook
- Cashbook recording in text files for archiving.
- Event protocol via email to Hotline: Additional text field for
problem description/ diagnosis remarks.
- Main Menu: Checks minmum window heigth/width and visibility during
start-up, moves window to visible position if necessary.
- winIPRO: Values are now displayed/printed with correct decimal
separator (UK)
Version from 19.03.2001 (15.57)
Version from 13.03.2001 (15.56)
Version from 08.03.2001 (15.55)
- Form printing: Pagination corrected for table printouts (cardfile
etc.)
- Order status control: "Info" field added for CL-orders
(corresponds to "reminder letter"). "Info" and "settled"
also added as criterion.
Version from 21.02.2001 (15.54)
- Order Status Control: Lens status "Ordered" corrected.
Version from 15.02.2001 (15.53)
- Order status control/Reception: "Picked up" column added to
table preferences.
- Voucher code determination updated
Version from 05.02.2001 (15.50)
- New: SMS- and E-Mail function in patient master data and order status
control.
- Internet-preferences: All passwords with confirmation for security
reasons. New: "POP before SMTP" function.
- Automatic data backup: Workshop device drivers are stopped and
re-started after backup
Version from 29.01.2001 (15.59)
- winIPRO Master Data management added for
CL-indication, care system, glasses for, patient characteristics.
- During most date inputs, it is now possible to open a calendar with a
right mouse-click.
Version from 25.01.2001 (15.58)
- Upper/lower case bug removed in CL item data entry.
Version from 22.01.2001 (15.57)
- New: winIPRO Web-Browser
- Order status control: Freely definable areas which can be called up
directly from the menu.
- Order survey glasses/CL in the patient screen: New column
"Prescription" available. Name of prescriber is shown. External prescriptions
are marked with a red cross.
- Contact lenses: Various
extensions (trial lens, extended lens data, lens view can be configured etc)
Version from 28.12.2000 (15.56)
- Insurance Co. master data: New entries now with institution code
search
Version from 20.12.2000 (15.55)
- Security function Glasses: Monitoring of subsequent changes of
additional payments.
- Password for "Clearing system" needed to change order type
to Old card file/Quotation
Version from 15.12.2000 (15.54)
- Order survey Glasses/CL in the patient screen: Order date is shown
instead of billing date
- Workshop devices: If a lens with the workshop status
"blocked" or "CNC-treated" is changed to "current", the
workshop status is deleted.
Version from 11.12.2000 (15.53)
- System preferences: User preferences extended (Prismm, minus
cylinders etc)
Version from 06.12.2000 (15.51)
- Order status control: Financial reminder stage editable and available
as criteria.
Version from 30.11.2000 (15.50
- winIPRO Acoustic connected to EPOS
New features in the winIPRO
Contact lens module (version from 22.01.2001 /15.57)
- New input fields added to the contact lens procedure window:
Dpt1/Dpt2, stabilisation axis and dividing line (for Addition).
- The contact lens-fitting with trial lenses can now be documented.
During the fitting, a new procedure is added for every trial lens. Tick the "Trial
lens" box in the basic data or during a new entry. The trial lens' item data are
marked green in the input fields and in the patient survey, thereby trial lenses can be
instantly recognised.
- Trial lenses are not shown in the CL settlement page, except for
settlements where the last procedure includes a trial lens or if prices were recorded with
a trial lens (eg for services).
- After the fitting using trial lenses is finished and a lens is to be
sold to the patient, enter a new procedure, untick the trial lens box and select the
procedure "Exchange/delivery according to trial lens".
- You can now select if you wish to have the LOT-number or the
complementary refraction shown in the procedure window. Do a right mouse-click on the grey
window background and select from the preferences. The default setup is complementary
refraction for trial lenses and LOT No for regular lenses. Both data groups can also be
edited in the "Complementary refraction, LOT etc." window after pressing the
button.
- It is now possible to accept refraction and cornea radii data from
the refraction report or the last CL; it is now also possible to accept the refraction
from the last glasses. Do a right mouse click on the background of the refraction area in
the CL order window.
- In the CL replacement scheme area, a new field "Active" has
been added. As long as this field stays ticked, the order will remain in the order status
control even if it has been paid and the account settled; new procedures may still be
added. Untick the box when the contract has ended and no further procedures will follow.
Then the order is deleted from the order status control as soon as it is paid.